EDM Project Management
Designed for consulting firms, EDM Project Manager is an all-in-one project management software designed to make day-to-day processes more easy, accurate, and actionable.
Seamlessly integrate front and back office processes, deliver projects on time and under budget. Unlock Peak Performance, simple, user-friendly, accessible anytime.
Contact us at info@electricaldm.com
Select Saved Project
Prefix Number
Client Name:
Project Description:
Electrical Code:
Project Equipment List:
Create New Project
3 Phase Motor Summaries:
Motor Specifications | Motor Values | Starter Specs | Protection | Cable Specs | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Motor ID | Motor Function | Motor Type | Design Code | System Voltage | Horse Power | RPM | Duty Cycle | PF% | Eff.% | kWatts | kvars | kva | Running Amps | Lock Rotor | Torque | FL Current | Starter Type | Starter | Fuse | Breaker | Cable Length | Cable Size | Voltage Drop % |
Single Phase Motor Summaries:
Motor Specifications | Motor Values | Starter Specs | Protection | Cable Specs | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Motor ID | System Voltage | Motor Type | Design Code | PF% | Eff.% | Horse Power | RPM | Duty Cycle | kWatts | Running Amps | Lock Rotor | Torque | FL Current | Starter | Starter Type | Fuse | Breaker | Cable Length | Cable Size | Voltage Drop % |
3 Phase Heater Summaries:
Heater Specifications | Heater Values | Starter Specs | Protection | Cable Specs | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heater ID | Heater Function | System Voltage | kWatts | Heater Mounting | Heater Type | Heater Kva | Fan Control Volt | Fan Motor Volt | Heater Amps | Fan Motor HP | Fan Motor RPM | Starter Type | Starter | Fuse | Breaker | Cable Length | Cable Size | Voltage Drop % |
Single Phase Heater Summaries:
Heater Specifications | Heater Values | Starter Specs | Protection | Cable Specs | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heater ID | Heater Volt | Heater Type | Haeter Function | kWatts | Heater Amps | Fan Voltage | Fan Motor HP | Fan Motor RPM | Fan Control Volt | Starter Type | Fuse | Breaker | Cable Length | Cable Size | Voltage Drop % | |||||
Unit | Full Voltage |
Motor Control Center Summaries:
MCC Specifications | MCC Values | Design Loads | Peak Loads | Operating Loads | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MCC ID | MCC Volt | MCC Type | MCC Function | kWatts | Heater Amps | Fan Voltage | Fan Motor HP | Fan Motor RPM | Fan Control Volt | Starter Type | Fuse | Breaker | Cable Length | Cable Size | Voltage Drop % | |||
Unit | Full Voltage |
HV Transformer Summaries:
Transformer Specifications | Primary Valves | Secondary Values | Teritary Values | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Transf ID | Transf Type | Primary Voltage | Secondary Voltage | Teritary Voltage | Impedance | Connectionc | Cooling Medium | Cooling Designation | Tap Changer | MVA | HZ | IZ | X/r | MVA | HZ | IZ | X/r | MVA | HZ | IZ | X/r |
HV Breaker Summaries:
Breaker Specifications | Interrupt Values | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Breaker ID | Duty | Breaker Type | Bkr Config | BIL Insulation | Current Rating | Trip Coils | Rating Factor | Short Circ kA | Interrupt Time | Trip Delay | Latch Current | |
Edit a Project
Create a New Project